Meter Configuration Menu
This menu allows you to configure the appearance of the Main Screen
meter characteristics, including: scale, ballistics, limits, reference levels,
and upper, middle, and lower segment set points, and colors.
Figure 5–25 Meter Configuration Menu
Scale: Rotating this knob steps through the scales for the level
meters. Seven selections are available as shown in Table 5–1 below.
Six settings are predefined; a seventh setting is user defined.
Meter
Configuration Menu
Configuration Selection
Menu
Main Screen
Menu
Configure Main
Screen
Main Screen
Configuration Menu
Configure
Meters
Meter Configuration Menu
Save / ExitHelp Cancel
AES
IEC1
VU
0 dBr
-72 dBr
12
-30 dBr
15
-20 dBr
0 dBr =
0 dBFS
4
Float
Bar
Top
Bottom
Scale
Bal-
listics
Limits
Reference
Upper
Segments
Middle
Segments
Lower
Segments
0
-60
-50
-40
-30
-10
-20
Lower
Scale
-30 dBr
50% FS
Division
Size
Table 5–1 Meter Limits and References
Scale
Bottom
Limit
Top Limit
Default
Reference
Default Color
Bounds
Default Ballistics
Lower Upper Float Bar
AES -72 dBFS 0.0 dBFS 0 dBFS = 0 dBFS -30 dBFS -20 dBFS
IEC
Type I
VU
VU -45 dBr +3.5 dBr -20 dBFS = 0 dBr -3 dBr 0 dBr VU
Extd VU -56 dBr +16.0 dBr -20 dBFS = 0 dBr -10 dBr 0 dBr VU